HYNADECOR FIRE RETARDANT ALUMINIUM COMPOSITE PANEL
 

The debate for fire properties and characteristics was always a key issue in the industry and was revived even more, with recent fires in buildings cladded with ACP, as in the case of Al Nasr Towers in 2007 (cladded with Alutile) and commercial building in Bucharest in 2009(cladded with Exalco-Bond). Fire is always regarded the most important element for building facades, due to the fatal implications that it might infer for the inhabitants of the building.

The correct terminology for the material FR is fire- Retardant (since it delays fire) and not fire resistant (since no material used in composite panels has been discovered to have full tolerance to fire). The most widely recognized standards are E-84 in US and DIN 4102-B1 in Europe.

It is a false impression that fire retardant materials are measured in terms of minutes to be burnt. There are also other parameters that can be equal importance, such as the toxicity of the fumes, spread of flames and droplets that fell.


The fire regulations vary heavily between countries, and reflect national differences, civic codes, cultural sensitivities and historical events, and environment factors. In Germany(in Europe when someone talks of best practices, usually means German practice) the local test has been based on average time plus 15 minutes that fire department needs to arrive at a building in flames in rush hour, and evacuate a typical 5 floor building from the inhabitants.

It’s definitely problematic to transfer building codes and regulations from one country to another, since there arise significant dissimilarities. European civic environments are characterized by low building (4-5 floors)densely built next to each other, so the fire regulations have been designed to prevent fire mainly from outside the building, and have subsequently given emphasis to the facades. Emirate civic environment, on the other hand, is characterized by high rise buildings, in relatively large distance from each other, and so we feel that more emphasis should be given to prevent fire mainly from inside the building. In this case, there should be given some importance to facades but we should also pay emphasis to barriers between the floors, as the fire can be transmitted easily from the space behind the cladding.

But also inferior product characteristics. In Far East, the aluminium skin

Thickness is seldom 0.5mm (as per the industry standard) and polyethylene is always recycled, sometimes from irrelevant products such as used car rubbers or supermarket bags.


HYNADECOR FIRE RETARDANT(FR) GRADE ACP

 

HYNADECOR FR is the non-combustible aluminium composite panel used in architecture. It consists of 3mm non-combustible inorganic mineral filled, polymer bonded halogen free core of LDPE sandwiched between 2 skins of 0.5mm thick Aluminium Coil (alloy designed 3000 H-14/16) making a consolidated panel finished with PVDF(Polyvinylidenflurid) coating containing minimum 70% Kynar 500® and 30% resin or Lumiflon® based coating on the topside. Lumiflon resins are thermo set resins (i.e. cured to form a coating that can’t be melted) they have no melting effect and offer a range of gloss as high as 90% and meets or exceed values expressed in AAMA 2605. HYNADECOR FR meets the highest requirements of the fire regulations and is therefore the ideal material for all areas where fire protection plays an important role– be it for high-rise or industrial buildings, public buildings, hospitals, hotels, tunnels or underground stations. Furthermore, with its proven product and processing properties, HYNADECOR FR offers architects designers’ unlimited opportunities for realizing their ideas. It is green material, as there is no harmful burning.

Fire behaviour:

 

HYNADECOR FR composite panels are not inflammable and so not actively contribute to combustion. During the life cycle of HYNADECOR FR composite panels, no environmentally hazardous substances are set free at any time and no toxic fumes are developed in the case of fire.

HYNADECOR FR has a non-combustible inorganic mineral filled, polymer bonded halogen free core and therefore generates no harmful gases in case of fire-also usable in areas with fire risk and difficult access for the fire bridge. It has excellent fire resistance compared to normal aluminium composite panel. It is a kind of environmentally friendly building material that offers excellent fire resistance and minimal gas generation when burnt. HYNADECOR FR with improved non-combustible mineral core is now under:

HYNADECOR has two kinds of fire retardant aluminum composite panel, B1 class and A2 class. For B1 class fire retardant aluminum composite panel, it contains: 50% - 55% flame retardant, the main ingredients are aluminum oxide (AlO) and magnesium oxide (MgO); When B1 grade panels are put on fire, it can be catch on fire after 5 minutes, and when the fire leave the panels, the fire on the panels will extinguish after 10 seconds.

For A2 class fireproof aluminum composite panel, it Contains 88% - 90% of the flame retardant, the main ingredients are aluminium hydroxide Al(OH)3 and magnesium hydroxide Mg(OH)2; it can be catch on fire after 20 minutes, and the fire will extinguish at once when the fire leave the panels.

Test Report on Physical Characteristics of State that Center of Building Materials Fireproof Panel:


Items Standard Index Test Value Individual Judgment
Density of surface Rating±0.5kg/m2 6.8kg/m2 Qualified
Impact strength 50kg.cmWithout paint off and crack Without paint off and crack Qualified
Bend strength ≥ 1OOMPa ≥ 1O4MPa Qualified
Flexuous modulus of elasticity ≥2.00 x lO4MPa 3.00 x lO4MPa Qualified
Through resistance ≥9.0KN 9.50KN Qualified
Cutting strength ≥ 28.OMPa 29.OMPa Qualified
1800peel strength ≥7.0N/mm ≥9.1N/mm Qualified
Resistance to change of temperature -400C~-800C20cycles without change Unchanged Qualified
Boiling water resistance Unchanged Unchanged Qualified
Coefficient of heat expansion ≥4.00 X lO-5 0C-1 2.93 X lO-5 0C-1 Qualified
Heat deformation temperature ≥1050C 1120C Qualified
The test result meets the index requirements of quality product of GB/T17748-1999

Test Report of Safety of State Quality Supervision & Inspection Center of Fireproof Building Materials Fireproof Panel.


Items Test method Technical index Result Conclusion
Minimum value of remaining length after burning GB/T8325-88 > 0 410 Qualified
Average value of remaining length after burning GB/T8325-88 ≥ 150 486 Qualified
Temperature of smoke GB/T8325-88 ≤ 200 116 Qualified
Height of the top of the flame, mm GB/T8326-88 150 15 Qualified
Grade of smoke density GB/T8327-88 ≤ 75 34 Qualified
Note: The technical index based on the regulation of uninflammable materials (Grade B1) of GB8624-1997.

TEST ITEM TEST CONDITION RESULT CONCLUSION TEST STANDARD
Fire safety test temperature of 73± 5 F
relative humidity of 50± 5%
Flame spread index: 10 Smoke developed value: 15 Class A   ASTM E-84-04

The class limits for flame spread detailed in ASTM E-84


Classification Flame spread at 1.5 min (mm) Final flame spread(mm)
Class 1/A
Class 2/B
165(+25)
215(+25)
165(+25)
455(+45)

Time for flame spread to reach
(s)
mm
Flame spread at 1.5min
(mm)  
Maximum flame spread
(mm)  
Time to reach maximum
flame spread
(s)  
165 215 265 455 710 60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60

Conclusion: The sample met the performance requirements of Class 1/Class A.

Testing for ASTM E-84.

Fire Propagation Test

Results:


Sub-index
i1
Sub-index
i2
Sub-index
i3
Total fire propagation
index I

The sample met the requirements of Class A.

Item 3: Fire Safety test for Surface Burning Characteristics in accordance with the procedures outlined in ASTM E 84-04.

The test results, calculated in accordance with ASTM E-84-04 for Flame Spread and Smoke Developed Values are as follows:

Test Specimen: Fireproof Aluminium Composite Panel

Flame Spread index*:10

Smoke Developed Value*: 15

Observations:

Ignition was noted at 300 seconds followed by charring, peeling and warping of the sample. At the conclusion of the test after burn was noted.

Test Results:

FIRE PROPAGATION TEST- ASTM E-84

Time mins t Specimen Temperature ◦C Ts Calibration Temperature ◦C Tc Ts- Tc/10t Sub Index of Performance
0.50
1.00
1.50
2.00
2.50
3.00
10
16
19
24
28
31
14
20
26
31
35
39
0.00
0.00
0.00
0.00
0.00
0.00
   






0.000
Total Index of Performance S = 0.000

Sub Index s1 - 0.00
Sun Index s2 - 0.00
Sub Index s3 - 0.00
Index of performance S - 0.00


TABLE 2 FIRE PERFORMANCE PROPERTIES
Properties 4mm 6mm
Surface burning characteristics, ASTM E-84
Smoke developed index 0 10
Flame spread index 0 0
Vertical transmission, ASTM E-108 (modified) Passed Passed
Ignition temperature, ASTM D-1929    
Flash Ignition 716oF(380oC)  
Self-Ignition 752oF(400oC)  
Rate of burning, ASTM D-635 CCI  

Specifications of core:

Core Halogen Free
Composition of core Inorganic compound: Minimum 90% Organic compound: Not more than 10%

Properties of PVDF Coating:

SNO DRY FILM PROPERTIES RESULT TEST STANDARD
1 Finish coat thickness 27(±3µm) ASTM D-7091
2 Formability(T-Bend) No peel off-2T, No Cracking ASTM D-4145
3 Reverse Impact ≥16* Paint No Peel Off ASTM D-2794
4 Cross hatch adhesion Test ≥ 3B ASTM D-3359
5 Boiling water adhesion test Passes ASTM D-3359-B
6 Chemical resistance: 10% HCL Passes ASTM-2605
Chemical resistance:70% HNO3   Passes AAMA-2605
Chemical Resistance:3% Detergent solution Passes AAMA-2605
Chemical resistance: Mortar Passes AAMA-2605
7 Colour retention(∆E) ≤ 5.0 ASTM D-2244/AAMA-2605
8 Gloss retention ≤ 70% ASTM D-523/AAMA 2605
9 Chalk resistance No Chalking ASTM D-4214/AAMA-2605
10 Salt Spray(4000 hrs) No Damage AAMA 2605
11 Humidity Resistance(4000 hrs) No Damage AAMA 2605

Mechanical Properties:

SNo PROPERTIES RESULTS TEST STANDARD
1 Thermal Conductance 5.79Btu/hr.ft 2.0F(32.9W/m2.0K) ASTM C518
2 Tensile strength ≥40MPa ASTM E8
3 Yield strength ≥3OMPa ASTM E8
4 Elongation 8805;3% ASTM E8
5 Deflection temperature under load 211°C ASTM D648
6 Liner thermal expansion 2.4mm/m at 100°C temp. difference EN 1999 1-1
7 Acoustic properties: Sound absorption factor as 0.05db ISO 354
Sound transmission loss Rw 27db min. ISO 717-1
8 Thermal Properties:
Thermal resistance R
0.002m2K/W DIN 52612
9 Panel dimension tolerances Thickness:±0.20mm  
Width:+4.0mm  
Length:+6.0mm  
10 Weight of panel Maximum 6KG/m²  
11 Resistance to spread of flame Class-B Min Appendix-4 UIC-564-2 OR
12 Deterioration of visibility of smoke Class-A Appendix-15 UIC-564-2 OR
13 Limiting oxygen index 32 Min IS:13501
14 Toxicity Less than 1 NCD-1409
15 Heat release rate(MARHE i.e. maximum average rate of heat emission in KW/m²) as specified in EN 45545-2:2013 R1(HL3)
50KW/m²
ISO 5660-1